- home /
- open-ted (eng) /
- tenders /
- 2024 /
- at /
- contract award notice /
- Pipettierroboter
Pipettierroboter
contract award noticeFollowing the summary about the notice 2024/S 002-002670 dispatched in the year 2024.
Contracting authority |
Medizinische Universität Innsbruck Innsbruck (AT332) more authorities |
Type of the contracting authority | Body governed by public law |
Main activity | Education |
Type of contract | Supplies |
Main CPV code |
|
Place of performance | Innsbruck (AT332) more |
Country | DE; - country: AT |
Document type | Contract award notice |
Procedure | Negotiated procedure without a call for competition |
Type of bid | Not applicable |
Award criteria | Not applicable |
Regulation | European Union, with participation of GPA countries |
Publication date | 2024-01-03 00:00:00 |
Deadline | 2024-04-07 00:00:00 |
Values | 388˙481.50 EUR (procurement total) |
You might be interested
Check raw information
View raw data from TED xml.
TECHNICAL_SECTION
1 RECEPTION_ID: 23-751061-001
1 DELETION_DATE: 20240407
1 FORM_LG_LIST: DE
1 COMMENTS: From Convertor
LINKS_SECTION
1 XML_SCHEMA_DEFINITION_LINK
1 OFFICIAL_FORMS_LINK
1 FORMS_LABELS_LINK
1 ORIGINAL_CPV_LINK
1 ORIGINAL_NUTS_LINK
CODED_DATA_SECTION
1 REF_OJS
2 COLL_OJ: S
2 NO_OJ: 2
2 DATE_PUB: 20240103
1 NOTICE_DATA
2 NO_DOC_OJS: 2024/S 002-002670
2 URI_LIST
3 --- URI_DOC value: https://ted.europa.eu/udl?uri=TED:NOTICE:002670-2024:TEXT:DE:HTML
2 LG_ORIG: DE
2 ISO_COUNTRY
INFO: AT2 IA_URL_GENERAL: https://www.i-med.ac.at/mypoint/
2 ORIGINAL_CPV: Detection and analysis apparatus
INFOCODE: 384300002 VALUES
3 --- VALUE value: 388481.50
2 REF_NOTICE
3 --- NO_DOC_OJS value: 2023/S 243-764589
1 CODIF_DATA
2 DS_DATE_DISPATCH: 20231229
2 AA_AUTHORITY_TYPE: Body governed by public law
INFOCODE: 62 TD_DOCUMENT_TYPE: Contract award notice
INFOCODE: 72 NC_CONTRACT_NATURE: Supplies
INFOCODE: 22 PR_PROC: Negotiated without a prior call for competition
INFOCODE: T2 RP_REGULATION: European Union, with participation by GPA countries
INFOCODE: 52 TY_TYPE_BID: Not applicable
INFOCODE: 92 AC_AWARD_CRIT: Lowest price
INFOCODE: 12 MA_MAIN_ACTIVITIES: Education
INFOCODE: L2 HEADING: 01B03
2 INITIATOR: 01
TRANSLATION_SECTION
1 ML_TITLES
2 ML_TI_DOC
3 --- TI_CY value: Aвcтpия
3 --- TI_TOWN value: Инсбрук
3 TI_TEXT
L: 4 --- key: (P) value: Уреди за детекция и за анализ
2 ML_TI_DOC
3 --- TI_CY value: Rakousko
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Snímací a analytické aparáty
2 ML_TI_DOC
3 --- TI_CY value: Østrig
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Apparater til fysisk eller kemisk analyse
2 ML_TI_DOC
3 --- TI_CY value: Österreich
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Erkennungs- und Analysegeräte
2 ML_TI_DOC
3 --- TI_CY value: Αυστρία
3 --- TI_TOWN value: Ίνσμπρουκ
3 TI_TEXT
L: 4 --- key: (P) value: Όργανα και συσκευές ανίχνευσης και ανάλυσης
2 ML_TI_DOC
3 --- TI_CY value: Austria
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Detection and analysis apparatus
2 ML_TI_DOC
3 --- TI_CY value: Austria
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Aparatos de detección y análisis
2 ML_TI_DOC
3 --- TI_CY value: Austria
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Detektorid ja analüüsiseadmed
2 ML_TI_DOC
3 --- TI_CY value: Itävalta
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Ilmaisimet ja analyysilaitteet
2 ML_TI_DOC
3 --- TI_CY value: Autriche
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Appareils de détection et d'analyse
2 ML_TI_DOC
3 --- TI_CY value: Ostair, an
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Detection and analysis apparatus
2 ML_TI_DOC
3 --- TI_CY value: Austrija
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Aparati za detekciju i analizu
2 ML_TI_DOC
3 --- TI_CY value: Ausztria
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Észlelő- és analizálóberendezések
2 ML_TI_DOC
3 --- TI_CY value: Austria
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Apparecchi per analisi e rivelazione
2 ML_TI_DOC
3 --- TI_CY value: Austrija
3 --- TI_TOWN value: Insbrukas
3 TI_TEXT
L: 4 --- key: (P) value: Detektoriai ir analizės aparatai
2 ML_TI_DOC
3 --- TI_CY value: Austrija
3 --- TI_TOWN value: Insbruka
3 TI_TEXT
L: 4 --- key: (P) value: Detektorierīces un analīzes ierīces
2 ML_TI_DOC
3 --- TI_CY value: l-Awstrija
3 --- TI_TOWN value: Innsbruk
3 TI_TEXT
L: 4 --- key: (P) value: Apparat tas-sejbien u l-analiżi
2 ML_TI_DOC
3 --- TI_CY value: Oostenrijk
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Detectie- en analyseapparatuur
2 ML_TI_DOC
3 --- TI_CY value: Austria
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Aparatura do wykrywania i analizy
2 ML_TI_DOC
3 --- TI_CY value: Áustria
3 --- TI_TOWN value: Insbruque
3 TI_TEXT
L: 4 --- key: (P) value: Aparelhos de detecção e análise
2 ML_TI_DOC
3 --- TI_CY value: Austria
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Aparate de detectare şi de analiză
2 ML_TI_DOC
3 --- TI_CY value: Rakúsko
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Prístroje na detekciu a rozbory
2 ML_TI_DOC
3 --- TI_CY value: Avstrija
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Aparati za odkrivanje in analizo
2 ML_TI_DOC
3 --- TI_CY value: Österrike
3 --- TI_TOWN value: Innsbruck
3 TI_TEXT
L: 4 --- key: (P) value: Detektions- och analysutrustning
1 ML_AA_NAMES
2 AA_NAME: Medizinische Universität Innsbruck
FORM_SECTION
1 F03_2014
2 LEGAL_BASIS
INFO: 32014L00242 CONTRACTING_BODY
3 ADDRESS_CONTRACTING_BODY
L: 4 --- key: (OFFICIALNAME) value: Medizinische Universität Innsbruck
L: 4 --- key: (ADDRESS) value: Innrain 52
L: 4 --- key: (TOWN) value: Innsbruck
L: 4 --- key: (POSTAL_CODE) value: 6020
INFO4: AT4 COUNTRY
L: 4 --- key: (CONTACT_POINT) value: Schiefer Rechtsanwälte GmbH
L: 4 --- key: (PHONE) value: +43 662840648
L: 4 --- key: (E_MAIL) value: mui-pipettierroboter@schiefer.at
L: 4 --- key: (URL_GENERAL) value: https://www.i-med.ac.at/mypoint/
L: 4 --- key: (URL_BUYER) value: https://i-med.vemap.com
3 CA_TYPE
3 CA_ACTIVITY
2 OBJECT_CONTRACT
3 TITLE
L: 4 --- key: (P) value: Pipettierroboter
3 CPV_MAIN
4 CPV_CODE
3 TYPE_CONTRACT
3 SHORT_DESCR
L: 4 --- key: (P) value: Beschaffung von zwei Pipettierrobotern
3 --- VAL_TOTAL value: 388481.50
3 NO_LOT_DIVISION
3 OBJECT_DESCR
4 SHORT_DESCR
5 P: Die MUI beabsichtigt die Lieferung, Installation, Inbetriebnahme sowie Wartung zweier Pipettierroboter zu vergeben.
4 AC
5 AC_PRICE
4 OPTIONS
4 OPTIONS_DESCR
5 P: Der Auftraggeber beabsichtigt nach der Etablierung des ersten Protokolls bei Gerät 1 die Etablierung eines zweiten Protokolls. Daher behält sich der Auftraggeber für das Gerät 1 vor, die Etablierung eines zweiten Protokolls (Lympho Track Klonalitäts-Kits) optional zu beauftragen.
4 NO_EU_PROGR_RELATED
2 PROCEDURE
3 PT_AWARD_CONTRACT_WITHOUT_CALL
4 D_ACCORDANCE_ARTICLE
5 D_TECHNICAL
4 D_JUSTIFICATION
5 P: Erläuterung:
5 P: Die von der MUI zu beschaffenden Geräte müssen folgende Mindestanforderungen erfüllen können:
5 P: • Die Geräte müssen über eine Grundausstattung mit allen technischen Bestandteilen, die für eine erfolgreiche
5 P: automatische Bearbeitung folgender kommerzieller Kits geeignet ist, verfügen:
5 P: o Gerät 1: IDT xGen DNA EZ Library Prep + xGen Hyb Capture
5 P: o Gerät 2: TWIST EF Library Prep + UDI AND Standard Hyb
5 P: • Die Geräte müssen mit einem integrierten „On Deck Thermocycler“ ausgestattet sein.
5 P: • Bei dem Gerät muss sichergestellt sein, dass es auf einem handelsüblichen Labor-Arbeitstisch platziert
5 P: werden kann („Tabletop“-Gerät oder ähnliche Umsetzung).
5 P: • Der Pipettierarm muss über mindestens acht individuell (assymetrisch) spreizbare Einzel-Pipettierkanäle
5 P: verfügen, die in der Lage sind, Einweg-Pipettenspitzen oder sonstige benötigte Werkzeuge ohne Kraftaufwand
5 P: mechanisch zu koppeln und abzuwerfen/abzulegen.
5 P: • Die Geräte müssen mit einem kompakten „Multimode“-Fluoreszenzleser ausgestattet sein, der über
5 P: mechanische Kopplung an den Pipettierarm flexibel zum notwendigen Einsatzort transportiert werden kann.
5 P: • Es muss eine zukünftige nachträgliche Etablierung weiterer Kits handelsüblicher Hersteller sollte möglich sein.
5 P: • Die Qualitätsparameter der Sequenzier-Bibliotheken (Insert-Länge, Enrichment-Effizienz, Uniformität, DuplikatRate) müssen mit denen von händisch hergestellten Sequenzier-Bibliotheken vergleichbar sein.
5 P: • Der Pipettierarm muss über mindestens acht individuell (assymetrisch) spreizbare Einzel-Pipettierkanäle
5 P: verfügen, die in der Lage sind, Einweg-Pipettenspitzen oder sonstige benötigte Werkzeuge ohne Kraftaufwand
5 P: mechanisch zu koppeln und abzuwerfen/abzulegen.
5 P: • Die Geräte müssen mit einem kompakten „Multimode“-Fluoreszenzleser ausgestattet sein, der über
5 P: mechanische Kopplung an den Pipettierarm flexibel zum notwendigen Einsatzort transportiert werden kann.
5 P: • Die Abnahme der Protokolle muss zwingend mit echten biologischen Proben erfolgen.
5 P: • Art und Frequenz von nachgewiesenen Veränderungen müssen zwischen manuell und maschinell
5 P: bearbeiteten Proben unter Beachtung methodisch bedingter Schwankungen vergleichbar sein.
5 P: Erläuterung:
5 P: Ein Großteil der vorstehenden Anforderungen wird nur vom Gerät von Hamilton Germany GmbH erfüllt. Die
5 P: Ausstattung ist erforderlich um den im klinischen Bereich einen einwandfreien Arbeitsablauf sicherzustellen
5 P: und die gesetzten Qualitätsparameter zu erfüllen. Ausschlaggebend ist insbesondere, dass die Abnahme der
5 P: Protokolle zwingend mit echten biologischen Proben erfolgt. Diese technischen Merkmale sind zur Deckung des
5 P: konkreten Bedarfs unabdingbar.
3 CONTRACT_COVERED_GPA
3 --- NOTICE_NUMBER_OJ value: 2023/S 243-764589
2 AWARD_CONTRACT
3 AWARDED_CONTRACT
L: 4 --- key: (DATE_CONCLUSION_CONTRACT) value: 2023-12-28
4 TENDERS
5 NB_TENDERS_RECEIVED: 1
4 CONTRACTORS
5 NO_AWARDED_TO_GROUP
5 CONTRACTOR
6 ADDRESS_CONTRACTOR
OFFICIALNAME: Hamilton Germany GmbH
ADDRESS: Lochhamer Schlag 11
TOWN: Gräfelfing
POSTAL_CODE: 82166
7 COUNTRY
6 NO_SME
4 VALUES
5 VAL_TOTAL: 388481.50
2 COMPLEMENTARY_INFO
3 ADDRESS_REVIEW_BODY
L: 4 --- key: (OFFICIALNAME) value: Bundesverwaltungsgericht
L: 4 --- key: (ADDRESS) value: Erdbergstraße 192-196
L: 4 --- key: (TOWN) value: Wien
L: 4 --- key: (POSTAL_CODE) value: 1030
INFO4: AT4 COUNTRY
L: 4 --- key: (E_MAIL) value: einlaufstelle@bvwg.gv.at
3 ADDRESS_MEDIATION_BODY
L: 4 --- key: (OFFICIALNAME) value: keine
L: 4 --- key: (TOWN) value: kein
INFO4: AT4 COUNTRY
3 REVIEW_PROCEDURE
L: 4 --- key: (P) value: .
3 --- DATE_DISPATCH_NOTICE value: 2023-12-29