Opendata, web and dolomites

OCT4IOL

Optical Coherence Tomography for Intraocular Lenses

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 OCT4IOL project word cloud

Explore the words cloud of the OCT4IOL project. It provides you a very rough idea of what is the project "OCT4IOL" about.

paradigms    implantation    surgery    accommodating    quantitative    partnership    replacement    full    instrument    age    delivering    accommodation    tomography    reduce    transparency    outcomes    segment    ocular    erc    generate    commercialization    technologies    investigates    refractive    cataract    quantification    errors    designs    correct    vivo    anterior    post    market    pace    despite    moves    optimal    intraocular    western    ip    marketability    envisioned    millions    proprietary    presbyopia    patients    line    oct    topography    techniques    mechanisms    grant    younger    coherence    quality    artificial    iols    capability    laboratory    45    accurate    frequent    reaching    evaluation    oct4iol    crystalline    premium    iol    ultimate    gt    restore    proof    brings    population    biometry    prototype    strategic    performed    patient    surgical    plan    vision    automatic    becomes    basic    demonstrated    eye    customization    optical    alliance    select    imaging    worldwide    lens    steady    nature    inspired    distortion   

Project "OCT4IOL" data sheet

The following table provides information about the project.

Coordinator
AGENCIA ESTATAL CONSEJO SUPERIOR DEINVESTIGACIONES CIENTIFICAS 

Organization address
address: CALLE SERRANO 117
city: MADRID
postcode: 28006
website: http://www.csic.es

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Spain [ES]
 Total cost 150˙000 €
 EC max contribution 150˙000 € (100%)
 Programme 1. H2020-EU.1.1. (EXCELLENT SCIENCE - European Research Council (ERC))
 Code Call ERC-2014-PoC
 Funding Scheme ERC-POC
 Starting year 2015
 Duration (year-month-day) from 2015-01-01   to  2016-06-30

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    AGENCIA ESTATAL CONSEJO SUPERIOR DEINVESTIGACIONES CIENTIFICAS ES (MADRID) coordinator 150˙000.00

Map

 Project objective

The replacement of the crystalline lens of the eye by an artificial intraocular lens (IOL) is one of the most frequent procedures worldwide (3 millions/year in Western Europe). The surgery is required to correct for the age-related loss in transparency (cataract), but it is also performed to correct for refractive errors, and may be envisioned to correct for presbyopia in a younger population (>45) with future accommodating IOLs that restore the eye focusing capability. Despite the development of new IOL designs and a steady market growth of IOLs (particularly of Premium IOLs, aiming at delivering optimal vision quality to the patient), the techniques to select the optimal IOL design have not evolved at a similar pace. As cataract surgery moves into new paradigms, access to ocular imaging-based technologies that allow accurate selection of the IOL and evaluation of the surgical outcomes becomes essential.

The PRESBYOPIA ERC-Advanced Grant investigates basic mechanisms of the crystalline lens accommodation, to propose nature-inspired IOL designs to correct presbyopia. With this aim, we have developed a laboratory prototype for full 3-D quantitative anterior segment Optical Coherence Tomography (OCT) based on our proprietary method to reduce distortion and automatic quantification. We have demonstrated the capabilities of this instrument to provide accurate crystalline lens topography in vivo and full 3-D optical biometry in cataract patients pre- and post- implantation of IOLs.

The OCT4IOL ERC-Proof of Concept will evaluate the marketability of this OCT line, generate new IP, developing a product commercialization plan, and reaching a strategic partnership alliance, with the ultimate goal of developing an instrument that brings eye surgery into new paradigms for IOL selection and customization in cataract surgery.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "OCT4IOL" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "OCT4IOL" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.1.1.)

ENUF (2019)

Evaluation of Novel Ultra-Fast selective III-V Epitaxy

Read More  

Aware (2019)

Aiding Antibiotic Development with Deep Analysis of Resistance Evolution

Read More  

MITOvTOXO (2020)

Understanding how mitochondria compete with Toxoplasma for nutrients to defend the host cell

Read More