Opendata, web and dolomites

ISSD

The Implantable Subcutaneous String Defibrillator, an innovative subcutaneous cardioverterdefibrillator for a new paradigm in cardiac rhythm management.

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 ISSD project word cloud

Explore the words cloud of the ISSD project. It provides you a very rough idea of what is the project "ISSD" about.

cardioverter    device    claiming    plan    overcome    introduces    impacts    seamless    pose    rates    patients    8m    stage    wireless    implantable    issd    solutions    replacement    fits    vascular    prevent    min    deployment    invisible    rechargeable    veins    barriers    implantation    europe2    cardiac    sme    halving    meet    fast    investment    dimension    efficiency    cyber    generators    350    lives    defibrillators    complications    chain    trade    technologies    subcutaneous    trials    carry    improves    countries    causes    demand    solid    transvenous    instrument    first    designed    inserted    arrest    helped    snake    procedure    subcutaneously    sound    security    scas    financial    threating    life    avoiding    death    almost    deploy    icds    move    icd    point    market    aesthetical    sca    totally    robustness    drawbacks    wires    leads    invested    clinical    comfort    outpatient    heart    3m    untouched    implanted    global    sudden    view    remaining    commercialisation    rapid   

Project "ISSD" data sheet

The following table provides information about the project.

Coordinator
NEWPACE LTD 

Organization address
address: 13 GRANITH ST
city: CAESAREA
postcode: 3088900
website: n.a.

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Israel [IL]
 Project website http://www.newpacemedical.com
 Total cost 71˙429 €
 EC max contribution 50˙000 € (70%)
 Programme 1. H2020-EU.2.1.1. (INDUSTRIAL LEADERSHIP - Leadership in enabling and industrial technologies - Information and Communication Technologies (ICT))
2. H2020-EU.2.3.1. (Mainstreaming SME support, especially through a dedicated instrument)
 Code Call H2020-SMEINST-1-2016-2017
 Funding Scheme SME-1
 Starting year 2017
 Duration (year-month-day) from 2017-11-01   to  2018-02-28

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    NEWPACE LTD IL (CAESAREA) coordinator 50˙000.00

Map

 Project objective

Sudden Cardiac Arrest (SCA) is a life-threating heart condition and one of the most common causes of death in developed countries claiming more than 350,000 lives per year in Europe2. There are currently two different implantable technologies to prevent SCAs: 1) Transvenous Implantable Cardioverter-Defibrillators (T-ICDs), which are implanted with wires that snake through veins into the heart; and 2) Subcutaneous Implantable Cardioverter-Defibrillators (S-ICD), which also have generators and leads but avoiding leads within the heart. However this solutions pose many drawbacks such as major complications to the vascular system, replacement needs, aesthetical and comfort impacts, complex implantation procedures and cyber-security issues.

The ISSD™ introduces a new dimension in subcutaneous ICDs. It is a totally integrated device fully inserted subcutaneously, with no leads within the heart, thus remaining the vascular system untouched. It is a wireless rechargeable device, halving replacement rates when compared to current technologies and it is totally seamless and integrated, so no generators or leads are needed. This makes the device almost invisible and improves patients comfort. It is designed from a cyber-security point of view and can be implanted in a rapid outpatient procedure (20 min on average).

So far, we have invested €8M which have helped us to ensure its robustness and efficiency and move into the commercialisation stage. To further develop the ISSD™, overcome market barriers and deploy it at a European and global level we need a further investment of €3M which will allow us to carry out clinical trials and set up a solid EU value chain able to meet the large demand expected during the first years of commercialisation.

The proposed work in Phase 1 of the SME instrument fits into our overall plan to reach the market by contributing the financial resources needed to plan a fast sound wider deployment of the ISSD™ and its market uptake.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "ISSD" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "ISSD" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.2.1.1.;H2020-EU.2.3.1.)

HUMEXE (2017)

HUman EXoskEleton

Read More  

Meshporto_smeIns1_2 (2018)

PsstMenu allows customers to place orders directly from home or restaurant tables using only a smartphone.

Read More  

Outsense Phase-1 (2017)

Toilet IoT sensor for medical monitoring and wellness tool

Read More