Opendata, web and dolomites

microMole

SEWAGE MONITORING SYSTEM FOR TRACKING SYNTHETIC DRUG LABORATORIES

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 microMole project word cloud

Explore the words cloud of the microMole project. It provides you a very rough idea of what is the project "microMole" about.

2007    planning    environment    suspicion    storage    recording    lowered    sensor    specificity    unodc    certain    collecting    stimulants    retrieving    emccda    apaan    threat    located    lea    miniaturized    secure    2011    groups    data    specialists    operations    dimension    caused    aiding    remote    court    sewage    figure    europol    rising    2010    1990    social    raid    prototype    contain    emcdda    sensors    investigators    crime    price    manufacturing    confined    micro    harvesting    chemical    precursor    severe    precursors    amphetamine    forensic    protection    initial    countries    enhanced    2008    worldwide    time    locating    installed    pipes    monitoring    law    privacy    stages    energy    waste    electro    power    housing    gsm    dismantled    area    200mm    suspicions    drugs    urban    periods    radio    tanks    mole    drug    communications    facilities    acceptance    ats    criminal    minimized    laboratories    material    track    consumption    operation    synthetic    mu    significantly    keeps    bmk    2009    reported    environmental   

Project "microMole" data sheet

The following table provides information about the project.

Coordinator
POLITECHNIKA WARSZAWSKA 

Organization address
address: PLAC POLITECHNIKI 1
city: WARSZAWA
postcode: 00 661
website: http://www.pw.edu.pl

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Poland [PL]
 Project website http://www.micromole.eu/
 Total cost 5˙423˙798 €
 EC max contribution 4˙992˙866 € (92%)
 Programme 1. H2020-EU.3.7. (Secure societies - Protecting freedom and security of Europe and its citizens)
 Code Call H2020-FCT-2014
 Funding Scheme IA
 Starting year 2015
 Duration (year-month-day) from 2015-09-01   to  2019-02-28

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    POLITECHNIKA WARSZAWSKA PL (WARSZAWA) coordinator 341˙875.00
2    FRAUNHOFER GESELLSCHAFT ZUR FOERDERUNG DER ANGEWANDTEN FORSCHUNG E.V. DE (MUNCHEN) participant 1˙356˙630.00
3    JGK TECH EHF IS (HAFNARFJORDUR) participant 599˙430.00
4    UNIVERSITEIT GENT BE (GENT) participant 544˙998.00
5    UNIVERSITE LYON 1 CLAUDE BERNARD FR (VILLEURBANNE CEDEX) participant 520˙000.00
6    UNIVERSITAET DER BUNDESWEHR MUENCHEN DE (NEUBIBERG) participant 380˙538.00
7    STICHTING KATHOLIEKE UNIVERSITEIT BRABANT NL (TILBURG) participant 293˙248.00
8    CENTRALNE LABORATORIUM KRYMINALISTYCZNE POLICJI PL (WARSZAWA) participant 283˙511.00
9    BUNDESKRIMINALAMT DE (Berlin) participant 282˙250.00
10    CAPSENZE HANDELSBOLAG SE (LUND) participant 230˙259.00
11    BLUE TECHNOLOGIES SP ZOO PL (WARSZAWA) participant 160˙125.00

Map

 Project objective

The threat of synthetic drugs is one of the most significant current drug problems worldwide. Amphetamine-Type Stimulants (ATS) are the second most widely used drugs. Since 1990, ATS manufacturing has been reported from more than 70 countries worldwide and the figure keeps rising. In 2008, 80 % of the amphetamine production facilities dismantled worldwide were located in Europe (UNODC, 2010) (EMCCDA, 2011). Organised Crime Groups are involved in ATS large-scale production (Europol, 2007) (EMCDDA, 2009). Since 2011, the wide availability of pre-precursors (like APAAN) significantly lowered the price of the controlled precursor BMK and caused severe environmental problems, taking the problem to a greater dimension.

The aim of this project is to design, develop and test a prototype of a system for legal recording, retrieving and monitoring operations of ATS and ATS precursor laboratories in urban areas. The sensor system will be installed within the sewage system and will track waste associated to ATS production. Criminal investigators and forensic specialists will use the system in case of: 1. initial general suspicion of ATS production in a certain area, for locating laboratories by monitoring the sewage system for long time periods; 2. strong suspicions that in a well confined area ATS is being produced, for collecting material for forensic analysis and potential use in court, and for aiding in the planning of LEA raid operations.

The μMole prototype will contain the following features: a) miniaturized system for 200mm sewage pipes, b) robust housing taking into account sewage system environment, c) minimized power consumption, d) enhanced operation time supported by energy harvesting, e) high-specificity electro-chemical sensors, f) integrated micro-tanks for sample storage, and g) secure GSM and radio communications for remote monitoring. Analysis of privacy law, data protection and social acceptance will be carried on at different stages.

 Deliverables

List of deliverables.
Prototype of the Agent core and MMS with basic functionality Other 2019-11-22 17:48:53
Prototype of the crawler robot and tool Demonstrators, pilots, prototypes 2019-11-22 17:48:53
Heat-sink realization concept Documents, reports 2019-11-22 17:48:53
Cooling structure design Documents, reports 2019-11-22 17:48:52
Implementation specification of the chemical sensors, the sensing subsystem and the ASIC Documents, reports 2019-11-22 17:48:52
Microfluidic passive system description and evaluation Documents, reports 2019-11-22 17:48:52
Revised prototype of the Agent core and MMS with basic functionality Other 2019-11-22 17:48:52
Technical and legal evaluation of the revised prototypes with improved sensing subsystem Documents, reports 2019-11-22 17:48:52
Full sensing subsystem with interface for external testing Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Prototype of the first version of the complete energy management subsystem Demonstrators, pilots, prototypes 2019-11-22 17:48:53
ASIC and the electrodes for internal testing Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Improved electrodes Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Revised prototypes of the first sensing and sample storage units Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Prototype of the re-design of the complete energy management subsystem Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Prototype of the Agent core and MMS with full functionality Other 2019-11-22 17:48:52
Sensing Unit - Technical and Legal evaluation Documents, reports 2019-11-22 17:48:52
Evaluation report of the revised energy-harvester Documents, reports 2019-11-22 17:48:52
Sensing Unit - First Prototype Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Transducers for active fluidic system Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Heat-sink prototype Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Sampling Unit - Technical and Legal evaluation Documents, reports 2019-11-22 17:48:52
Revised sensing subsystem Demonstrators, pilots, prototypes 2019-11-22 17:48:52
Website of the project Websites, patent fillings, videos etc. 2019-11-22 17:48:51
Design of the microfluidic structure Documents, reports 2019-11-22 17:48:51
Design of the transducers Documents, reports 2019-11-22 17:48:51
Design of the crawler robot and tool Documents, reports 2019-11-22 17:48:51
Patents Websites, patent fillings, videos etc. 2019-11-22 17:48:53
Scientific publications Documents, reports 2019-11-22 17:48:53

Take a look to the deliverables list in detail:  detailed list of microMole deliverables.

 Publications

year authors and title journal last update
List of publications.
2018 Beloglazova N., De Rycke E., Hedstrom M., Leman O., Dubruel P. Puetz M., De Saeger S.
Capacitive biosensor based on the synthetic receptors for multiplex monitoring of amphetamine-type stimulants in water system
published pages: , ISSN: , DOI:
2019-11-22
2018 Hauser F., Rößler T., Putz M.
Biotransformation of benzyl methyl ketone and N-formylamphetamine in wastewater treatment plant effluent and sludge
published pages: , ISSN: , DOI:
2019-11-22
2018 El-Akaad S., Putz M., Hedstrom M., De Saeger S., Beloglazova N.
Molecular Imprinted Polymers For the Capacitive Detection of ATS
published pages: , ISSN: , DOI:
2019-11-22
2017 Trynda A., Jaworowicz M.
Stability of markers specific for amphetamine synthesis by Leuckart method in different environment conditions
published pages: , ISSN: , DOI:
2019-11-22
2018 J. Gallardo-Gonzalez, A. Saini, A. Baraket, S. Boudjaoui, A. Alcácer, A. Streklas, F. Teixidor, N. Zine, J. Bausells, A. Errachid
A highly selective potentiometric amphetamine microsensor based on all-solid-state membrane using a new ion-pair complex, [3,3′-Co(1,2-closo-C2B9H11)2]− [C9H13NH]+
published pages: 823-829, ISSN: 0925-4005, DOI: 10.1016/j.snb.2018.04.001
Sensors and Actuators B: Chemical 266 2019-11-22
2017 Van der Sloot, B
Micromole
published pages: , ISSN: , DOI:
2019-11-22
2018 Zakaria Ayroud, Juan Gallardo-Gonzalez, Abdoullatif Baraket, Marie Hangouet, Albert Alcácer, Angelos Streklas, Joan Bausells, Abdelhamid Errachid, Nadia Zine
A Highly Sensitive Impedimetric Metamitron Microsensor Based on All-Solid-State Membrane Using a New Ion-Pair Complex, [3,3′-Co(1,2-closo-C2B9H11)2]−[C10H11ON4]+
published pages: 1093, ISSN: 2504-3900, DOI: 10.3390/proceedings2131093
Proceedings 2/13 2019-11-22
2018 Frank M. Hauser, Janneke W. Hulshof, Thorsten Rößler, Ralf Zimmermann, Michael Pütz
Characterisation of aqueous waste produced during the clandestine production of amphetamine following the Leuckart route utilising solid-phase extraction gas chromatography-mass spectrometry and capillary electrophoresis with contactless conductivity dete
published pages: 1368-1382, ISSN: 1942-7603, DOI: 10.1002/dta.2394
Drug Testing and Analysis 10/9 2019-11-22
2019 Frank M. Hauser, Tim Metzner, Thorsten Rößler, Michael Pütz, Steffen Krause
Real-time wastewater monitoring as tool to detect clandestine waste discharges into the sewage system
published pages: 1-13, ISSN: 1527-5922, DOI: 10.1080/15275922.2019.1566295
Environmental Forensics 2019-11-22
2018 Van der Sloot, B.
Botnets & Sewage monitoring
published pages: , ISSN: , DOI:
2019-11-22
2017 E. De Rycke, K. Graniczkowska, N. Beloglazova, M. Hedström, P. Dubruel, S. De Saeger
Capacitive based sensor for trace detection of amphetamine type stimulants in water
published pages: , ISSN: , DOI:
2019-11-22
2017 Pütz M., Hauser F.
EU-Projekt microMole (2015-2018): Detection of clandestine drug laboratories via the sewage system Structure elucidation of route-specific APAAN markers and their prevalence in Dutch and German amphetamine seizures of 2009 – 2016
published pages: , ISSN: , DOI:
2019-11-22
2017 F. M. Hauser, T. Rößler, D. Weigel, J. Hulshof, R. Zimmermann, M. Pütz
New Approaches to Gather Information About the Clandestine Production of Amphetamine
published pages: , ISSN: , DOI:
2019-11-22
2018 Abhishek Sonu, Abdoullatif Baraket, Selim Boudjaoui, Juan Gallardo, Nadia Zine, Monique Sigaud, Marie Hangouet, Albert Alcácer, Angelos Streklas, Joan Bausells, Abdelhamid Errachid
Solid State Gas Sensor Based on Polyaniline Doped with [3,3′-Co(1,2-C2B9H11)2]−1 for Detection of Acetone: Diagnostic to Heart Failure Disease
published pages: 1086, ISSN: 2504-3900, DOI: 10.3390/proceedings2131086
Proceedings 2/13 2019-11-22
2017 Graniczkowska K., Beloglazova N.V., De Saeger S.
Design of synthetic receptors for monitoring of ATS-based stimulants
published pages: , ISSN: , DOI:
2019-11-22
2018 Leverenz E., Becker K.-F., Koch M., Straube S., Poetter H., Lang K.-D.
Energy Autarkic Wireless Sensor Node for Reliable Long – Term Exposure to Domestic Waste Water in a Sewage System
published pages: , ISSN: , DOI:
2019-11-22
2018 Spies P., Mateu L., Pollack M.
Bipolarer‚ ultra low voltage‘ DC-DC-Wandler-Chip mit MPPT für funkvernetzte Sensoren
published pages: , ISSN: , DOI:
2019-11-22
2019 J. Gallardo-Gonzalez, A. Baraket, S. Boudjaoui, T. Metzner, F. Hauser, T. Rößler, S. Krause, N. Zine, A. Streklas, A. Alcácer, J. Bausells, A. Errachid
A fully integrated passive microfluidic Lab-on-a-Chip for real-time electrochemical detection of ammonium: Sewage applications
published pages: 1223-1230, ISSN: 0048-9697, DOI: 10.1016/j.scitotenv.2018.11.002
Science of The Total Environment 653 2019-11-22
2018 Leverenz E.
Self-sufficient sensor system for harsh environment
published pages: , ISSN: , DOI:
2019-11-22
2017 F. M. Hauser, T. Rößler, D. Weigel, R. Zimmermann, M. Pütz
Analysis of chemical waste from illegal amphetamine syntheses - Supporting the forensic assessment of clandestine drug laboratories as part of the EU project ‘microMole’
published pages: , ISSN: , DOI:
2019-11-22
2018 Frank M. Hauser, Thorsten Rößler, Janneke W. Hulshof, Diana Weigel, Ralf Zimmermann, Michael Pütz
Identification of specific markers for amphetamine synthesised from the pre-precursor APAAN following the Leuckart route and retrospective search for APAAN markers in profiling databases from Germany and the Netherlands
published pages: 671-680, ISSN: 1942-7603, DOI: 10.1002/dta.2296
Drug Testing and Analysis 10/4 2019-11-22
2016 Graniczkowska K., Beloglazova N., De Saeger S.
Synthesis of MIPs towards precursors and intermediates of illicit drugs and their following application in sensing unit
published pages: , ISSN: , DOI:
2019-11-22
2017 Nadia El Alami El Hassani, Abdoullatif Baraket, Ernandes Taveira Tenório Neto, Michael Lee, J-Pablo Salvador, M-pilar Marco, Joan Bausells, Nezha El Bari, Benachir Bouchikhi, Abdelhamid Elaissari, Abdelhamid Errachid, Nadia Zine
Novel strategy for sulfapyridine detection using a fully integrated electrochemical Bio-MEMS: Application to honey analysis
published pages: 282-288, ISSN: 0956-5663, DOI: 10.1016/j.bios.2016.08.083
Biosensors and Bioelectronics 93 2019-11-22
2017 J. Gallardo-González, A. Baraket, A. Bonhomme, N. Zine, M. Sigaud, J. Bausells, A. Errachid
Sensitive Potentiometric Determination of Amphetamine with an All-Solid-State Micro Ion-Selective Electrode
published pages: 348-358, ISSN: 0003-2719, DOI: 10.1080/00032719.2017.1326053
Analytical Letters 51/3 2019-11-22
2017 Kinga Graniczkowska, Michael Pütz, Frank M. Hauser, Sarah De Saeger, Natalia V. Beloglazova
Capacitive sensing of N-formylamphetamine based on immobilized molecular imprinted polymers
published pages: 741-747, ISSN: 0956-5663, DOI: 10.1016/j.bios.2016.09.083
Biosensors and Bioelectronics 92 2019-11-22
2016 Frank M. Hauser; Thorsten Rößler; Diana Weigel; Ralf Zimmermann; Michael Pütz
Characterisation of chemical waste from illegal amphetamine synthesis to support forensic assessment of clandestine drug laboratories
published pages: , ISSN: , DOI:
2019-11-22

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "MICROMOLE" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "MICROMOLE" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.3.7.)

EMYNOS (2015)

nExt generation eMergencY commuNicatiOnS

Read More  

ResiStand (2016)

Increasing disaster Resilience by establishing a sustainable process to support Standardisation of technologies and services

Read More  

EU-CIVCAP (2015)

Preventing and responding to conflict: developing EU CIVilian CAPabilities for a sustainable peace

Read More