Explore the words cloud of the 4D-PET project. It provides you a very rough idea of what is the project "4D-PET" about.
The following table provides information about the project.
Coordinator |
AGENCIA ESTATAL CONSEJO SUPERIOR DEINVESTIGACIONES CIENTIFICAS
Organization address contact info |
Coordinator Country | Spain [ES] |
Total cost | 2˙048˙386 € |
EC max contribution | 2˙048˙386 € (100%) |
Programme |
1. H2020-EU.1.1. (EXCELLENT SCIENCE - European Research Council (ERC)) |
Code Call | ERC-2015-AdG |
Funding Scheme | ERC-ADG |
Starting year | 2017 |
Duration (year-month-day) | from 2017-01-01 to 2021-12-31 |
Take a look of project's partnership.
# | ||||
---|---|---|---|---|
1 | AGENCIA ESTATAL CONSEJO SUPERIOR DEINVESTIGACIONES CIENTIFICAS | ES (MADRID) | coordinator | 2˙048˙386.00 |
The main objective of 4D-PET is to develop an innovative whole-body PET scanner based in a new detector concept that stores 3D position and time of every single gamma interaction with unprecedented resolution. The combination of scanner geometrical design and high timing resolution will enable developing a full sequence of all gamma-ray interactions inside the scanner, including Compton interactions, like in a 3D movie. 4D-PET fully exploits Time Of Flight (TOF) information to obtain a better image quality and to increase scanner sensitivity, through the inclusion in the image formation of all Compton events occurring inside the detector, which are always rejected in state-of-the-art PET scanners. The new PET design will radically improve state-of-the-art PET performance features, overcoming limitations of current PET technology and opening up new diagnostic venues and very valuable physiological information
year | authors and title | journal | last update |
---|---|---|---|
2018 |
Efthymios Lamprou, Albert Aguilar, Andrea González-Montoro, Jose M. Monzó, Gabriel Cañizares, Sofia Iranzo, Luis F. Vidal, Liczandro Hernández, Pablo Conde, Sebastian Sánchez, Filomeno Sánchez, Antonio J. González, José M. Benlloch PET detector block with accurate 4D capabilities published pages: 132-136, ISSN: 0168-9002, DOI: 10.1016/j.nima.2017.11.002 |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 912 | 2019-08-29 |
2017 |
A.J. Gonzalez, A. Gonzalez-Montoro, A. Aguilar, G. Cañizares, R. MartÃ, S. Iranzo, E. Lamprou, S. Sanchez, F. Sanchez, J.M. Benlloch A scintillator geometry suitable for very small PET gantries published pages: C12018-C12018, ISSN: 1748-0221, DOI: 10.1088/1748-0221/12/12/c12018 |
Journal of Instrumentation 12/12 | 2019-08-29 |
2018 |
Antonio J. Gonzalez, Stuart S. Berr, Gabriel Cañizares, Andrea Gonzalez-Montoro, Abel Orero, Carlos Correcher, Ahmadreza Rezaei, Johan Nuyts, Filomeno Sanchez, Stan Majewski, Jose M. Benlloch Feasibility Study of a Small Animal PET Insert Based on a Single LYSO Monolithic Tube published pages: , ISSN: 2296-858X, DOI: 10.3389/fmed.2018.00328 |
Frontiers in Medicine 5 | 2019-08-29 |
2019 |
Antonio J. Gonzalez, Andrea Gonzalez-Montoro, Luis F. Vidal, Julio Barbera, Sebastian Aussenhofer, Liczandro Hernandez, Laura Moliner, Filomeno Sanchez, Carlos Correcher, Edwin J. Pincay, Gabriel Canizares, Efthymios Lamprou, Sebastian Sanchez, Juan V. Catret, Santiago Jimenez-Serrano, Jorge Cabello, Markus Schwaiger, Amadeo Iborra, Thibaut Merlin, Dimitris Visvikis, Jose M. Benlloch Initial Results of the MINDView PET Insert Inside the 3T mMR published pages: 343-351, ISSN: 2469-7311, DOI: 10.1109/trpms.2018.2866899 |
IEEE Transactions on Radiation and Plasma Medical Sciences 3/3 | 2019-08-29 |
2017 |
A. Gonzalez-Montoro, F. Sanchez, S. Majewski, S. Zanettini, J.M. Benlloch, A.J. Gonzalez Highly improved operation of monolithic BGO-PET blocks published pages: C11027-C11027, ISSN: 1748-0221, DOI: 10.1088/1748-0221/12/11/c11027 |
Journal of Instrumentation 12/11 | 2019-08-29 |
2019 |
Andrea Gonzalez-Montoro, Antonio J Gonzalez Performance comparison of large-area SiPM arrays suitable for gamma ray detectors published pages: 45013, ISSN: 2057-1976, DOI: 10.1088/2057-1976/ab0f6e |
Biomedical Physics & Engineering Express 5/4 | 2019-08-29 |
2018 |
V. Ilisie, V. Giménez-Alventosa, L. Moliner, F. Sánchez, A.J. González, M.J. RodrÃguez-Ãlvarez, J.M. Benlloch Building blocks of a multi-layer PET with time sequence photon interaction discrimination and double Compton camera published pages: 74-83, ISSN: 0168-9002, DOI: 10.1016/j.nima.2018.03.076 |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 895 | 2019-06-13 |
2017 |
V. Ilisie, V. Giménez-Alventosa, L. Moliner, A. Aguilar, E. Lamprou, A. González, F. Sánchez, J.M. Benlloch Improving PET sensitivity with a Compton algorithm published pages: 12012, ISSN: 1742-6588, DOI: 10.1088/1742-6596/931/1/012012 |
Journal of Physics: Conference Series 931 | 2019-06-13 |
2019 |
Andrea González-Montoro, Filomeno Sánchez, Peter Bruyndonckx, Gabriel Cañizares, Jose M. Benlloch, Antonio J. González Novel method to measure the intrinsic spatial resolution in PET detectors based on monolithic crystals published pages: 58-67, ISSN: 0168-9002, DOI: 10.1016/j.nima.2018.12.056 |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 920 | 2019-08-29 |
2018 |
Antonio J. Gonzalez, Filomeno Sanchez, Jose M. Benlloch Organ-Dedicated Molecular Imaging Systems published pages: 388-403, ISSN: 2469-7311, DOI: 10.1109/trpms.2018.2846745 |
IEEE Transactions on Radiation and Plasma Medical Sciences 2/5 | 2019-08-29 |
2018 |
Andrea González-Montoro, Filomeno Sánchez, Rosana MartÃ, Liczandro Hernández, Albert Aguilar, Julio Barberá, Juan V. Catret, Gabriel Cañizares, Pablo Conde, Efthymios Lamprou, Francisco Martos, Sebatián Sánchez, Luis F. Vidal, Jose M. Benlloch, Antonio J. González Detector block performance based on a monolithic LYSO crystal using a novel signal multiplexing method published pages: 372-377, ISSN: 0168-9002, DOI: 10.1016/j.nima.2017.10.098 |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 912 | 2019-08-29 |
2019 |
Marta Freire, Andrea Gonzalez-Montoro, Filomeno Sanchez, Antonio J. Gonzalez Calibration of PET Detectors Based on Monolithic Blocks Using Voronoi Diagrams published pages: , ISSN: , DOI: |
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) | 2019-09-05 |
2019 |
Marta Freire, Andrea Gonzalez-Montoro, Filomeno Sanchez, Jose M. Benlloch, Antonio J. Gonzalez Calibration of Gamma Ray Impacts in Monolithic-Based Detectors Using Voronoi Diagrams published pages: , ISSN: 2469-7311, DOI: |
IEEE Transactions on Radiation and Plasma Medical Physics | 2019-09-05 |
2019 |
Efthymios Lamprou, Antonio J. Gonzalez, Filomeno Sanchez, Jose M. Benlloch Exploring TOF Capabilities of PET Detector Blocks Based on Large Monolithic Crystals and Analog SiPMs published pages: , ISSN: 1120-1797, DOI: |
Physics Medica: European Joournal Medical Physics | 2019-09-05 |
2018 |
Efthymios Lamprou, Andrea González-Montoro, Gabriel Cañizares, Victor Ilisie, Filomeno Sánchez, Marta Freire, Liczandro Hernández, Luis F. Vidal, John Barrio, Antonio J. González, José M. Benlloch TOF-PET Detectors Based on ASIC Technology and Analog SiPMs published pages: , ISSN: , DOI: |
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) | 2019-09-05 |
2018 |
Efthymios Lamprou, Andrea González-Montoro, Gabriel Cañizares, Victor Ilisie, John Barrio,
Filomeno Sánchez, Antonio J. González, José Maria Benlloch Characterization of TOF-PET Detectors Based on Monolithic Blocks and ASIC-Readout published pages: , ISSN: , DOI: |
2017 Real Time Conference | 2019-09-05 |
Are you the coordinator (or a participant) of this project? Plaese send me more information about the "4D-PET" project.
For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.
Send me an email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.
Thanks. And then put a link of this page into your project's website.
The information about "4D-PET" are provided by the European Opendata Portal: CORDIS opendata.
Life-inspired complex molecular systems controlled by enzymatic reaction networks
Read MoreHighlY performing proton exchange membrane water electrolysers with reinforceD membRanes fOr efficient hydrogen GENeration
Read MoreRedefining the esophageal stem cell niche – towards targeting of squamous cell carcinoma
Read More