RENERGISE

Innovative management of energy recovery for reduction of electrical power consumption on fuel consumption

 Coordinatore MILTECH HELLAS AE 

 Organization address address: METAXA STREET 90
city: PEANIA
postcode: 19002

contact info
Titolo: Mr.
Nome: Spanoudakis
Cognome: John
Email: send email
Telefono: 302107000000

 Nazionalità Coordinatore Greece [EL]
 Totale costo 475˙042 €
 EC contributo 344˙735 €
 Programma FP7-JTI
Specific Programme "Cooperation": Joint Technology Initiatives
 Code Call SP1-JTI-CS-2010-05
 Funding Scheme JTI-CS
 Anno di inizio 2011
 Periodo (anno-mese-giorno) 2011-07-01   -   2014-07-31

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    MILTECH HELLAS AE

 Organization address address: METAXA STREET 90
city: PEANIA
postcode: 19002

contact info
Titolo: Mr.
Nome: Spanoudakis
Cognome: John
Email: send email
Telefono: 302107000000

EL (PEANIA) coordinator 200˙255.50
2    UNIVERSITY OF PATRAS

 Organization address address: UNIVERSITY CAMPUS RIO PATRAS
city: RIO PATRAS
postcode: 26500

contact info
Titolo: Prof.
Nome: Emmanuel
Cognome: Tatakis
Email: send email
Telefono: 302611000000
Fax: 302611000000

EL (RIO PATRAS) participant 144˙480.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

dc    efficiency    generator    converter    vrms    pfc    kw    ac    voltage    always    boost    topologies    moreover    power    conversion    pm    electric    specifically    converters   

 Obiettivo del progetto (Objective)

'The issue of high efficiency has to be dealt with appropriate converter design; more specifically, the research team will study and develop the following solutions: (i) AC/DC conversion will be implemented by the use of parallel converters. These converters will be hierarchically controlled, depending on the recovered energy amount. So each time the number of “active” converters will be the one that matches electrical power generation. This way the converters will always operate close to their nominal power, where they perform maximum efficiency, maximizing also the whole AC/DC conversion efficiency under any point of operation. Moreover this is a modular design approach, which enables the implementation of different power levels. The exact power level for each converter module and its dynamic behavior will be determined during simulation and evaluation process. (ii)AC/DC modules shall have unity power factor and low THD (less than 5%) at the generator side (PFC converters); this way, synchronous generator is not charged with reactive power and electromagnetic compatibility issues are eliminated. ECRG-UP has significant experience in the development of high-efficiency PFC converter topologies and control techniques, based on PWM DC/DC topologies, as well as by the development of a 2kW PFC on board charger for electric vehicles. The selection of the PFC converter topology initially depends on the output rms voltage value of the PM generator. More specifically, if the peak AC voltage is always lower than DC bus voltage (270V) then boost type topologies can be considered; otherwise step down configurations have to be adopted. Generally, boost type topologies are considered to be more suitable for PFC applications in the range of 1 – 10kW, due to continuous input current shape that they produce Moreover the production of low AC voltage (100Vrms – 160Vrms) by the PM generator eases human security against electric shock.'

Altri progetti dello stesso programma (FP7-JTI)

FECOPROGEN (2013)

"FeCo based magnetic alloys with high strength and minimized iron losses, for new high speed aerospace generator"

Read More  

TILTOP (2010)

Efficient Shape Optimization of Intake and Exhaust of a Tiltrotor Nacelle

Read More  

ESTERA (2011)

Multi-level Embedded Closed-Loop Control System for Fluidic Active Flow Control Actuation Applied in High-Lift and High-Speed Aircraft Operations

Read More