HIFUSWI-INTRACARDIAC

High-intensity focused ultrasound intracardiac ablation with real-time monitoring using shear-wave imaging

 Coordinatore INSTITUT NATIONAL DE LA SANTE ET DE LA RECHERCHE MEDICALE (INSERM) 

 Organization address address: 101 Rue de Tolbiac
city: PARIS
postcode: 75654

contact info
Titolo: Dr.
Nome: Laurence
Cognome: Lomme
Email: send email
Telefono: +33 1 43 62 27 02
Fax: +33 1 43 62 27 01

 Nazionalità Coordinatore France [FR]
 Totale costo 193˙594 €
 EC contributo 193˙594 €
 Programma FP7-PEOPLE
Specific programme "People" implementing the Seventh Framework Programme of the European Community for research, technological development and demonstration activities (2007 to 2013)
 Code Call FP7-PEOPLE-2011-IIF
 Funding Scheme MC-IIF
 Anno di inizio 2012
 Periodo (anno-mese-giorno) 2012-10-15   -   2014-10-14

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    INSTITUT NATIONAL DE LA SANTE ET DE LA RECHERCHE MEDICALE (INSERM)

 Organization address address: 101 Rue de Tolbiac
city: PARIS
postcode: 75654

contact info
Titolo: Dr.
Nome: Laurence
Cognome: Lomme
Email: send email
Telefono: +33 1 43 62 27 02
Fax: +33 1 43 62 27 01

FR (PARIS) coordinator 193˙594.80

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

lesion    temperature    treatment    monitoring    cardiac    size    perform    time    ablation    contact    risks    real    hifu    imaging    ultrasound    therapy    rf    swi   

 Obiettivo del progetto (Objective)

'Arrhythmias are a major cause of death and disability worldwide and their prevalence is expected to rise with the aging of the population. Recent technological advances have led to the development of new treatments based on radio-frequency (RF) catheter ablation to treat and even cure these conditions. However, challenges in treatment persist. RF ablation is currently performed via direct contact with the endocardium, limiting the depth of tissue injury unless high temperatures are used, which lead to higher risks of clot formation. Another major limitation is the lack of combined imaging modality for real-time monitoring of the treatment and for accurate assessment of the lesion extent. Our objective is to construct an ultrasound-based intra-cardiac ultrasound therapy/imaging system that can perform ablation using high-intensity focused ultrasound (HIFU) and can monitor the size and temperature of the ablation lesion using shear wave imaging (SWI). The specific aims of are 1) to develop an intra-cardiac hybrid system to perform HIFU, real-time temperature and lesion size monitoring using SWI, 2) Validate and optimize the imaging/therapy system in an animal model and 3) Demonstrate the feasibility of real-time RF ablation monitoring in patients using SWI. This project is tailored to facilitate the transfer of knowledge of the experienced researcher in imaging the with ultrasound at very high frame-rate the electromechanical properties of the heart. Upon completion, this project will result in the development of an intra-cardiac ultrasound system that allows performing non-contact ablation transmurally while monitoring the lesion site growth and temperature in real time. The capability of ablating at any location in the thickness of the myocardium while simultaneously assess the size of the lesion, has the potential to accelerate procedures, reduce the risks, and, provide a new approach to assess the success of the ablation.'

Altri progetti dello stesso programma (FP7-PEOPLE)

IRN2010 (2010)

Israel Researchers' Night 2010

Read More  

BIOFUEL (2010)

Biofuels from Solid Wastes

Read More  

DARE (2012)

"Cross-Layer Design of Adaptive, Reliable and Energy Efficient Systems"

Read More