POPCORN

Development of corneal biomechanical model. Dynamic topographical characterization based on 3D plenoptic imaging

 Coordinatore ALICANTE OFTALMOLOGICA SL 

 Organization address address: AVENIDA DENIA 78
city: ALICANTE
postcode: 3016

contact info
Titolo: Dr.
Nome: David
Cognome: Piñero
Email: send email
Telefono: +34 965155000
Fax: 34965155748

 Nazionalità Coordinatore Spain [ES]
 Totale costo 1˙415˙543 €
 EC contributo 1˙067˙000 €
 Programma FP7-SME
Specific Programme "Capacities": Research for the benefit of SMEs
 Code Call FP7-SME-2013
 Funding Scheme BSG-SME
 Anno di inizio 2013
 Periodo (anno-mese-giorno) 2013-09-01   -   2016-02-29

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    ALICANTE OFTALMOLOGICA SL

 Organization address address: AVENIDA DENIA 78
city: ALICANTE
postcode: 3016

contact info
Titolo: Dr.
Nome: David
Cognome: Piñero
Email: send email
Telefono: +34 965155000
Fax: 34965155748

ES (ALICANTE) coordinator 120˙403.53
2    BIOTRONICS 3D LIMITED

 Organization address address: PARK PLACE 1
city: LONDON
postcode: E14 4BE

contact info
Titolo: Mr.
Nome: Haralambos
Cognome: Hatzakis
Email: send email
Telefono: +44 2070930903

UK (LONDON) participant 442˙203.04
3    COSTRUZIONI STRUMENTI OFTALMICI C.S.O. SRL

 Organization address address: VIA DEGLI STAGNACCI 12 E
city: BADIA A SETTIMO
postcode: 50018

contact info
Titolo: Mr.
Nome: Riccardo
Cognome: Nicoletti
Email: send email
Telefono: +39 055722191

IT (BADIA A SETTIMO) participant 335˙375.47
4    OPTOELECTRONICA - 2001 SA

 Organization address address: ATOMISTILOR STREET 409
city: MAGURELE
postcode: 77125

contact info
Titolo: Ms
Nome: Mirela
Cognome: Trupina
Email: send email
Telefono: +40 214574498

RO (MAGURELE) participant 126˙863.96
5    THE UK INTELLIGENT SYSTEMS RESEARCH INSTITUTE LIMITED

 Organization address address: MIDDLE ASTON HOUSE
city: OXFORDSHIRE
postcode: OX25 5PT

contact info
Titolo: Mr.
Nome: Paul
Cognome: Tattersall
Email: send email
Telefono: 441665000000

UK (OXFORDSHIRE) participant 20˙394.00
6    "ASOCIACION INDUSTRIAL DE OPTICA, COLOR E IMAGEN"

 Organization address address: NICOLAS COPERNICO - PARQUE TECNOLOGICO 7-13
city: "PATERNA, VALENCIA"
postcode: 46980

contact info
Titolo: Ms.
Nome: Elena
Cognome: Boronat Peidro
Email: send email
Telefono: +34 961318051

ES ("PATERNA, VALENCIA") participant 13˙775.00
7    UNIVERSIDAD DE ZARAGOZA

 Organization address address: CALLE PEDRO CERBUNA 12
city: Zaragoza
postcode: 50009

contact info
Titolo: Mr.
Nome: óscar
Cognome: López
Email: send email
Telefono: +34 976761000

ES (Zaragoza) participant 7˙985.00
8    VISIONSENSE LTD

 Organization address address: HAMAGSHIMIM STREET 20
city: PETACH-TIKVA
postcode: 49348

contact info
Titolo: Mr.
Nome: Avi
Cognome: Yaron
Email: send email
Telefono: 2014501712
Fax: 97237617143

IL (PETACH-TIKVA) participant 0.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

errors    detecting    vivo    technique    accurate    before    invasive    refractive    patients    treatments    evaluation    model    biomechanical    patient    corneal    eye    negative    cornea    successful    measuring    popcorn    imaging    avoiding    surgery    laser   

 Obiettivo del progetto (Objective)

'Uncorrected refractive errors are the second leading cause of blindness. Procedures detecting and correcting those errors, such as regular eye exams, glasses or contact lenses or refractive laser based surgery, could thereby transform the lives of millions of people. It is known that successful laser based refractive eye surgery can reduce or even cure common vision refractive errors, as well as, degenerative disorders like keratoconus, which is due to a corneal disorder. But while refractive surgery is becoming more affordable and safer, results are not as successful as they should be. As a consequence, this technique might not be recommendable for everybody, thus a detailed patient evaluation of his or her cornea should be made before deciding whether a refractive laser based surgery is adequate or not.

Based on this fact, the main objective of the POPCORN project is to develop a non-invasive and accurate corneal prediction system. This system will be based on a new imaging technology that will generate a personalised and in-vivo biomechanical model of the patient's cornea. This model will be used to predict the biomechanical behaviour and status of the cornea after surgery. This will allow detecting and avoiding possible risks and negative side effects that could lead to the need of further additional treatments or even, long-term consequences in the visual health of the patients.

This technology development will be possible thanks to the introduction of plenoptic imaging techniques that will allow generating the specific in-vivo patient model without any invasive technique. This will increase the comfort of the evaluation, while being highly accurate and providing precise diagnosis of corneal diseases. Until now, assessing the biomechanical properties of corneal tissue has not been possible besides measuring the Corneal Hysteresis parameter through an Ocular Response Analyser (ORA). This restrains practitioners and researchers from measuring nothing but merely geometrical aspects of the cornea, such as thickness and topography. The newly developed POPCORN system will allow a meticulous evaluation of patients before a laser based surgical procedure, avoiding future negative long-term side effects or patients being wrongly reoriented to other not as effective treatments.'

Altri progetti dello stesso programma (FP7-SME)

TRANSCOSME (2008)

Transnational Cooperation of the European Network of NCP SME

Read More  

MILD-DRY (2012)

Novel microwave-assisted vacuum drying for heat sensitive foods

Read More  

HEFEST (2008)

Smart fire-retardant coatings based on intumescent nanocomposites

Read More