Coordinatore | COMMISSARIAT A L ENERGIE ATOMIQUE ET AUX ENERGIES ALTERNATIVES
Organization address
address: RUE LEBLANC 25 contact info |
Nazionalità Coordinatore | France [FR] |
Totale costo | 3˙253˙918 € |
EC contributo | 1˙745˙752 € |
Programma | FP7-JTI
Specific Programme "Cooperation": Joint Technology Initiatives |
Code Call | FCH-JU-2009-1 |
Funding Scheme | JTI-CP-FCH |
Anno di inizio | 2011 |
Periodo (anno-mese-giorno) | 2011-01-01 - 2014-06-30 |
# | ||||
---|---|---|---|---|
1 |
COMMISSARIAT A L ENERGIE ATOMIQUE ET AUX ENERGIES ALTERNATIVES
Organization address
address: RUE LEBLANC 25 contact info |
FR (PARIS 15) | coordinator | 414˙574.00 |
2 |
TEKNOLOGIAN TUTKIMUSKESKUS VTT
Organization address
address: TEKNIIKANTIE 4 A contact info |
FI (ESPOO) | participant | 292˙276.00 |
3 |
HTceramix SA
Organization address
address: av des Sports 26 contact info |
CH (Yverdo-les-Bains) | participant | 276˙345.00 |
4 |
ECOLE POLYTECHNIQUE FEDERALE DE LAUSANNE
Organization address
address: BATIMENT CE 3316 STATION 1 contact info |
CH (LAUSANNE) | participant | 268˙887.00 |
5 |
UNIVERSITA DEGLI STUDI DI SALERNO
Organization address
address: VIA GIOVANNI PAOLO II 132 contact info |
IT (FISCIANO (SA)) | participant | 174˙434.00 |
6 |
HyGear Fuel Cell Systems B.V.
Organization address
address: Westervoortsedijk 73 contact info |
NL (Arnhem) | participant | 161˙422.00 |
7 |
EIFER EUROPAISCHES INSTITUT FUR ENERGIEFORSCHUNG EDF-KIT EWIV
Organization address
address: EMMY NOETHER STRASSE 11 contact info |
DE (KARLSRUHE) | participant | 105˙450.00 |
8 |
EBZ Entwicklungs- und Vertriebsgesellschaft Brennstoffzelle mbH
Organization address
city: Dresden contact info |
DE (Dresden) | participant | 52˙364.00 |
Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.
'Today, main expectation for SOFC stationary systems competitiveness is to exceed a durability of 40 000 h, an objective which is not today reached except for very specific designs. A better understanding and detection of the failure mechanisms and the internal condition of stacks is of major importance for the introduction of the SOFC technology. If, massive SOFC stack or auxiliary failure can be easily detected by the control system, it is not currently the case for insidious abnormal operating conditions that accelerate the degradation of the SOFC stack, impacting seriously its performances other the long run and ultimately the life expectancy of the stack. These insidious phenomena can come either from within the stack itself (ex. a SRU distribution channel blocked), or from minor system failures (ex. abnormal decrease of performance of a fuel blower). DESIGN sets out on the detection of slow and hidden phenomena that nevertheless have strong and detrimental long-term effects on the performance and durability of the SOFC stack. The project proposes to study the influence of slowly-damaging conditions on measures performed on the stack sub-components: the Cells, the Single Repeating Units (SRU) and smaller stacks. Identification of characteristic signatures of these degradation phenomena at the lower level will be subsequently transposed at the stack level, to provide a way to diagnose slow degradation phenomena in a commercial SOFC stack, through appropriate data processing of measures provided by limited sensors. The main outputs of the project will be: 1.Identification of relevant sensors and signals to be monitored to diagnose degradation phenomena; 2.A data analysis methodology to be applied to measured signals; 3.A set of characteristic signatures for the different degradation phenomena at the local and stack level, to be compared with the actual sensor signal to diagnose long-term degradation conditions; 4.Recommendations for operation recovery.'
A particularly promising fuel cell technology has had difficulty reaching the required hours of service without degradation. Scientists are developing diagnostic technology that may just lead to a market breakthrough.