Coordinatore | CSEM CENTRE SUISSE D'ELECTRONIQUE ET DE MICROTECHNIQUE SA - RECHERCHE ET DEVELOPPEMENT
Organization address
address: RUE JAQUET DROZ 1 contact info |
Nazionalità Coordinatore | Switzerland [CH] |
Totale costo | 9˙917˙888 € |
EC contributo | 6˙699˙928 € |
Programma | FP7-NMP
Specific Programme "Cooperation": Nanosciences, Nanotechnologies, Materials and new Production Technologies |
Code Call | FP7-2013-NMP-ENV-EeB |
Funding Scheme | CP-IP |
Anno di inizio | 2013 |
Periodo (anno-mese-giorno) | 2013-10-01 - 2017-09-30 |
# | ||||
---|---|---|---|---|
1 |
CSEM CENTRE SUISSE D'ELECTRONIQUE ET DE MICROTECHNIQUE SA - RECHERCHE ET DEVELOPPEMENT
Organization address
address: RUE JAQUET DROZ 1 contact info |
CH (NEUCHATEL) | coordinator | 1˙284˙567.00 |
2 |
SCHNEIDER ELECTRIC INDUSTRIES SAS
Organization address
address: RUE JOSEPH MONIER 35 contact info |
FR (RUEIL MALMAISON) | participant | 1˙018˙950.00 |
3 |
EQUA SIMULATION AB
Organization address
address: Rasundavaegen 100 contact info |
SE (SOLNA) | participant | 649˙280.00 |
4 |
IBM IRELAND LIMITED
Organization address
address: "IBM House, Shelbourne Road" contact info |
IE (Ballsbridge) | participant | 497˙000.00 |
5 |
NXP SEMICONDUCTORS NETHERLANDS BV
Organization address
address: High Tech Campus 60 contact info |
NL (EINDHOVEN) | participant | 438˙853.00 |
6 |
"TEKEVER - TECNOLOGIAS DE INFORMACAO, S.A."
Organization address
address: RUA DA LEZIRIA 1 contact info |
PT (OBIDOS) | participant | 374˙475.00 |
7 |
FUNDACIO INSTITUT DE RECERCA DE L'ENERGIA DE CATALUNYA
Organization address
address: C/ JARDINS DE LES DONES DE NEGRE 1 contact info |
ES (SANT ADRIA DE BESOS) | participant | 369˙592.00 |
8 |
CORK INSTITUTE OF TECHNOLOGY
Organization address
address: ROSSA AVENUE BISHOPSTOWN contact info |
IE (CORK) | participant | 348˙480.00 |
9 |
Nome Ente NON disponibile
Organization address
city: Colomiers contact info |
FR (Colomiers) | participant | 337˙240.00 |
10 |
TECHNISCHE UNIVERSITAET DRESDEN
Organization address
address: HELMHOLTZSTRASSE 10 contact info |
DE (DRESDEN) | participant | 302˙000.00 |
11 |
AMIRES SRO
Organization address
address: GOLFOVA 938/13 contact info |
CZ (PRAHA 10) | participant | 229˙900.00 |
12 |
COMMUNAUTE D'AGGLOMERATION DE LA ROCHELLE
Organization address
address: RUE SAINT MICHEL 6 contact info |
FR (LA ROCHELLE) | participant | 214˙516.00 |
13 |
CITTA DI TORINO
Organization address
address: PIAZZA PALAZZO DI CITTA 1 contact info |
IT (TORINO) | participant | 212˙800.00 |
14 |
ZEDFACTORY EUROPE LIMITED
Organization address
address: SANDMARTIN WAY 21 contact info |
UK (WALLINGTON) | participant | 143˙040.00 |
15 |
UNIVERSITE DE LA ROCHELLE
Organization address
address: Avenue Albert-Einstein 23 contact info |
FR (LA ROCHELLE) | participant | 142˙435.00 |
16 |
POLITECNICO DI TORINO
Organization address
address: Corso Duca degli Abruzzi 24 contact info |
IT (TORINO) | participant | 136˙800.00 |
17 |
IBM IRELAND PRODUCT DISTRIBUTION LIMITED
Organization address
address: SHELBOURNE ROAD BALLSBRIDGE contact info |
IE (DUBLIN 4) | participant | 0.00 |
Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.
'Today, Building Energy Performance Simulation (BEPS) analysis tends to show a large discrepancy with real energy performance. Most cases are due to gross mistakes rather than fundamental inadequacy of available technology and methods. The reasons are manifold. Highly simplified calculation methods are used far beyond their domain of validity. Assumed boundary conditions such as occupant behaviour are not in accordance with actual usage; gross malfunctions in control and HVAC systems are left undetected in the commissioning process, while thermal bridges and distribution system losses are left without attention. Moreover, metered and sub-metered data are not used efficiently in calculation tools and engineering based simulation models during the Measurement and Verification (M&V) phase. TRIBUTE aims at minimizing the gap between computed and measured energy performances through the improvement of the predictive capability of a state-of-the-art commercial BEPS. TRIBUTE will extend the use of this tool to the commissioning and operation stages of a building. For existing buildings, M&V techniques will be developed and deployed to connect the BEPS model in real time to the pivotal wireless sensing and control systems of a monitored building. This involves modelling building systems to a higher fidelity than done today, developing technology for on-line identification of building key parameters, and automatically adapting the on-line, real time BEPS to the actual building’s state. In addition, BHM and EFM application will compare measured data to the then improved predicted metrics and will enable detecting building deviations. Advanced data mining methods will help evaluate these deviations. Subsequent Energy Efficiency Diagnostic Rules and optimization methods will provide cost effective and corrective retrofit actions accordingly. The methodology and tools will be evaluated in the context of three different building types and locations.'