KEEPEMALIVE

Knowledge to Enhance the Endurance of PEM fuel cells by Accelerated LIfetime Verification Experiments

 Coordinatore STIFTELSEN SINTEF 

 Organization address address: Strindveien 4
city: TRONDHEIM
postcode: 7465

contact info
Titolo: Dr.
Nome: Ann Mari
Cognome: Svensson
Email: send email
Telefono: 4798230450
Fax: 4773594011

 Nazionalità Coordinatore Norway [NO]
 Totale costo 2˙874˙206 €
 EC contributo 1˙264˙582 €
 Programma FP7-JTI
Specific Programme "Cooperation": Joint Technology Initiatives
 Code Call FCH-JU-2008-1
 Funding Scheme JTI-CP-FCH
 Anno di inizio 2010
 Periodo (anno-mese-giorno) 2010-01-01   -   2013-06-30

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    STIFTELSEN SINTEF

 Organization address address: Strindveien 4
city: TRONDHEIM
postcode: 7465

contact info
Titolo: Dr.
Nome: Ann Mari
Cognome: Svensson
Email: send email
Telefono: 4798230450
Fax: 4773594011

NO (TRONDHEIM) coordinator 320˙450.00
2    IRD FUEL CELLS A/S (INDUSTRIAL RESEARCH & DEVELOPMENT A/S)

 Organization address address: KULLINGGADE 31
city: SVENDBORG
postcode: 5700

contact info
Titolo: Mr.
Nome: Henning Boegelund
Cognome: Pedersen
Email: send email
Telefono: +45 63633000
Fax: +45 63633001

DK (SVENDBORG) participant 237˙213.00
3    CENTRE NATIONAL DE LA RECHERCHE SCIENTIFIQUE

 Organization address address: Rue Michel -Ange 3
city: PARIS
postcode: 75794

contact info
Titolo: Dr.
Nome: Jocelyn
Cognome: Mere
Email: send email
Telefono: 33467613535
Fax: 33467043236

FR (PARIS) participant 220˙481.00
4    FUMA-TECH GESELLSCHAFT FUER FUNKTIONELLE MEMBRANEN UND ANLAGENTECHNOLOGIE MBH

 Organization address address: AM GRUBENSTOLLEN 11
city: ST INGBERT
postcode: 66386

contact info
Titolo: Dr.
Nome: Bernd
Cognome: Bauer
Email: send email
Telefono: 49689492650
Fax: 496895000000

DE (ST INGBERT) participant 153˙336.00
5    TECHNISCHE UNIVERSITAET GRAZ

 Organization address address: Rechbauerstrasse 12
city: GRAZ
postcode: 8010

contact info
Titolo: Dr.
Nome: Viktor
Cognome: Hacker
Email: send email
Telefono: 433169000000
Fax: 433169000000

AT (GRAZ) participant 134˙975.00
6    EIFER EUROPAISCHES INSTITUT FUR ENERGIEFORSCHUNG EDF-KIT EWIV

 Organization address address: EMMY NOETHER STRASSE 11
city: KARLSRUHE
postcode: 76131

contact info
Titolo: Mr.
Nome: August
Cognome: Guenter
Email: send email
Telefono: +49 72161051377
Fax: +49 721 61051332

DE (KARLSRUHE) participant 91˙653.00
7    STICHTING ENERGIEONDERZOEK CENTRUM NEDERLAND

 Organization address address: WESTERDUINWEG 3
city: PETTEN
postcode: 1755 LE

contact info
Titolo: Dr.
Nome: Gaby
Cognome: Janssen
Email: send email
Telefono: 31224564803
Fax: 31224568489

NL (PETTEN) participant 61˙595.00
8    SEAS-NVE HOLDING AS

 Organization address address: HOVEDGADEN 36
city: SVINNINGE
postcode: 4520

contact info
Titolo: Mrs.
Nome: Kristina
Cognome: Juelsgaard
Email: send email
Telefono: +457029 2574
Fax: +45 5631 4455

DK (SVINNINGE) participant 22˙737.00
9    JRC -JOINT RESEARCH CENTRE- EUROPEAN COMMISSION

 Organization address address: Rue de la Loi 200
city: BRUSSELS
postcode: 1049

contact info
Titolo: Ms.
Nome: Josephina
Cognome: Pijls
Email: send email
Telefono: 31224565332
Fax: 31224565608

BE (BRUSSELS) participant 22˙142.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

small    related    stationary    corresponding    operation    cell    keepemalive    realistic    lifetime    fuel    stressing    pemfc    performance    situ    degradation    statistical    materials   

 Obiettivo del progetto (Objective)

'Small scale stationary Combined Heat and Power (µ-CHP) generation is foreseen as a significant future market for fuel cells. Among the fuel cell types, the Proton Exchange Membrane Fuel Cell (PEMFC) technology is by far dominating the small scale stationary demonstration and field trials (~90%). The PEMFC has advantages related to high electric efficiency and excellent load following properties. A major hurdle to commercialisation, however, is their insufficient lifetime under realistic operation conditions. KEEPEMALIVE aims to establish improved understanding of degradation and failure mechanisms, accelerated stress test protocols, sensitivity matrix and lifetime prediction models for Low Temperature PEMFC to enable a lifetime of 40 000h at realistic operation conditions for stationary systems, in compliance with performance and costs targets. Main KEEPEMALIVE targets are to establish a robust and efficient methodology to identify & quantify main factors (and interactions) causing degradation/failure when imposed to stressing conditions and to characterise changes in PEMFC materials’ properties and corresponding performance losses using statistical designed experiments KEEPEMALIVE uses an integrated, iterative approach, using advanced statistical experiment design and result evaluation. Quantitative data obtained in situ from cell &stack tests under stressing conditions, are complemented by ex situ testing of materials, revealing corresponding changes in properties. Joint efforts of SMEs, energy companies and research community, including links to other related European activities, will contribute to strengthening Europe’s competitiveness in this area.'

Altri progetti dello stesso programma (FP7-JTI)

ELECTRA (2014)

ELECTRA

Read More  

CLEANCOMPFIELD (2010)

Construction and Assembly of a Prototype Surface Pre-treatment Tool for In-filed use

Read More  

HPEM (2012)

Development of key technology components for high performance electric motors

Read More