INTELSENS

Integrated Laser Sensor for Exhaled Anaesthetic Agent Monitoring

 Coordinatore THE CHANCELLOR, MASTERS AND SCHOLARS OF THE UNIVERSITY OF CAMBRIDGE 

 Organization address address: The Old Schools, Trinity Lane
city: CAMBRIDGE
postcode: CB2 1TN

contact info
Titolo: Ms.
Nome: Dawn
Cognome: Barker
Email: send email
Telefono: -334722
Fax: -334167

 Nazionalità Coordinatore United Kingdom [UK]
 Totale costo 178˙874 €
 EC contributo 178˙874 €
 Programma FP7-PEOPLE
Specific programme "People" implementing the Seventh Framework Programme of the European Community for research, technological development and demonstration activities (2007 to 2013)
 Code Call FP7-PEOPLE-2007-2-1-IEF
 Funding Scheme MC-IEF
 Anno di inizio 2008
 Periodo (anno-mese-giorno) 2008-06-01   -   2010-05-31

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    THE CHANCELLOR, MASTERS AND SCHOLARS OF THE UNIVERSITY OF CAMBRIDGE

 Organization address address: The Old Schools, Trinity Lane
city: CAMBRIDGE
postcode: CB2 1TN

contact info
Titolo: Ms.
Nome: Dawn
Cognome: Barker
Email: send email
Telefono: -334722
Fax: -334167

UK (CAMBRIDGE) coordinator 0.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

medical    cambridge    patients    pas    manufacturers    he    patient    monitoring    recovery    techniques    induced    chemical    industrial    trace    photoacoustic    sensor    university    anaesthetics    blood    background    propofol    team    surgery    optical    online    stream    exist    engineers    sensing    uk    exhaled    breath    times    dramatically    technique    quality    anaesthetic    concentrations    acute    ultraviolet    tailoring    clinical    drug    administration    dosage    effectiveness    physicists    applicant    gas    detection    levels    monitor    impact    commercial    anaesthesia    professionals   

 Obiettivo del progetto (Objective)

'The application of a novel ultra-sensitive photoacoustic gas sensor is proposed to allow for online monitoring of an intravenously administered anaesthetic agent, which is exhaled at trace levels with the patient’s breath during surgery. We respond to a real and acute need for clinical online monitoring of anaesthetic concentrations in the patient’s blood stream during surgery. In the drafting of this proposal, the Applicant, himself from a physical sciences background, has extensively consulted with Prof. T. Absalom and Dr. D Wheeler, Division of Anaesthesia, School of Clinical Medicine, University of Cambridge, UK to define the clinical problem at the core of this application. The project focuses on the monitoring of propofol, one of the most widely used intravenous anaesthetics in general anaesthesia. Currently the effectiveness of propofol induced anaesthesia is only assessed symptomatically, based on highly subjective and unsophisticated scoring. A viable online capability to monitor exhaled trace levels of propofol in patients does not currently exist but would dramatically improve the level of control over its administration. It would both improve the quality of anaesthetic management by tailoring dosage to the individuals’ needs, reduce clinical recovery times and patient aftercare with associated cost benefits. The project is based on a unique interdisciplinary ensemble of physicists, chemical engineers, medical professionals and potential commercial manufacturers focusing on a high impact engineering challenge. The Applicant has an excellent academic background. He has already gained international recognition in terms of invited conference contributions. He has been one of the key players to develop the proposed sensor technology. The proposed high impact project in a multidisciplinary environment at the University of Cambridge, UK, would fully qualify the Applicant for an independent research post at an internationally recognised research institution.'

Introduzione (Teaser)

A novel technique of measuring a common anaesthetic drug in the breath under surgery will help doctors gauge dosage and avoid complications.

Descrizione progetto (Article)

General anaesthesia is very often necessary before surgical operations, but it remains a tricky component of surgery that must be monitored closely. There is an acute need to monitor anaesthetic concentrations in the patient's blood stream during surgery.

The Intelsens project, fully funded by the EU, set out to develop a new way to monitor the patient's levels of propofol, one of the most common anaesthetics. The project is proposing a gas sensor to identify trace levels of the anaesthetic in the patient's breath.

Currently, the effectiveness of propofol-induced anaesthesia is only assessed according to symptoms presented by the patient. The ability to monitor exhaled trace levels of propofol in patients does not currently exist but would dramatically improve the level of control over its administration.

The project team succeeded in developing a new optical sensing concept to trace levels of propofol in the breath. This is expected to improve healthcare quality by tailoring dosage to individual needs, while reducing clinical recovery times and postoperative care, along with associated costs.

Upon injection, propofol is transported into the blood stream and traces of the drug appear in the exhaled breath. In medical feasibility studies using mass spectrometry and gas chromatography the volume of propofol in parts-per-billion had previously been estimated but the techniques were unsuitable for surgery.

After many tests using ultraviolet and infrared rays to measure propofol, the team elaborated the most optimum strategy for optical detection of the drug. The technology relied on what is known as photoacoustic spectroscopy (PAS), built to measure ultraviolet absorption. Laser excitation was also used in the process, and successful equipment was ultimately developed and fine-tuned.

The project proved the concept beyond doubt and was accomplished through active collaboration between physicists, chemical engineers, medical professionals and commercial medical systems developers.The results have raised interest in other research institutes and industrial systems manufacturers.

A follow-up project is aimed at a clinical evaluation of the PAS technique for online propofol monitoring in patients undergoing surgery. The novel techniques have also shown great potential beyond the current application in fields such as atmospheric trace gas sensing, exhaled breath disease diagnostics, industrial process monitoring as well as pollutant detection in the liquid phase.

Altri progetti dello stesso programma (FP7-PEOPLE)

CFILP (2011)

Characterization of factors involved in proliferation of Bacillus subtilis L-forms

Read More  

MYPLANET (2008)

Massively Parallel Computations of Combustion and Emission Simulations

Read More  

TOPO_HOX (2015)

Mapping the face in the somatosensory brainstem: genetic and activity-dependent mechanisms

Read More