EXP-HEAT

Energy recovery in new and retrofitted heat pumps using a dedicated expander concept

 Coordinatore NATIONAL TECHNICAL UNIVERSITY OF ATHENS - NTUA 

 Organization address address: HEROON POLYTECHNIOU 9 ZOGRAPHOU CAMPUS
city: ATHINA
postcode: 15780

contact info
Titolo: Ms.
Nome: Georgia
Cognome: Mertzelou
Email: send email
Telefono: +30 2107721348
Fax: +30 2107724181

 Nazionalità Coordinatore Greece [EL]
 Totale costo 1˙773˙520 €
 EC contributo 1˙369˙104 €
 Programma FP7-SME
Specific Programme "Capacities": Research for the benefit of SMEs
 Code Call FP7-SME-2013
 Funding Scheme BSG-SME
 Anno di inizio 2013
 Periodo (anno-mese-giorno) 2013-12-01   -   2016-05-31

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    NATIONAL TECHNICAL UNIVERSITY OF ATHENS - NTUA

 Organization address address: HEROON POLYTECHNIOU 9 ZOGRAPHOU CAMPUS
city: ATHINA
postcode: 15780

contact info
Titolo: Ms.
Nome: Georgia
Cognome: Mertzelou
Email: send email
Telefono: +30 2107721348
Fax: +30 2107724181

EL (ATHINA) coordinator 58˙080.00
2    EUREFTEC AB

 Organization address address: WIENHOJDEN 6
city: NORRTALJE
postcode: 76192

contact info
Titolo: Mr.
Nome: Kenneth
Cognome: Weber
Email: send email
Telefono: +46 702826499

SE (NORRTALJE) participant 433˙400.00
3    THERMOGAS ANONYMI EMPORIEI EISAGOGIKI KAI TECHNIKI ETAITEIA EIDON THERMANSIS KAI CLIMATISMOU

 Organization address address: LEOFOROS ANTHOUSIS 12
city: PALLENE
postcode: 153 51

contact info
Titolo: Dr.
Nome: Sotirios
Cognome: Katsimichas
Email: send email
Telefono: +30 2106665552

EL (PALLENE) participant 309˙360.00
4    ITALGROUP SRL

 Organization address address: VIA ANTONIO PACINOTTI 20/22 FRAZIONE GAGGIO DI PIANO
city: CASTELFRANCO EMILIA
postcode: 41013

contact info
Titolo: Mr.
Nome: Luciano
Cognome: Ghiaroni
Email: send email
Telefono: 39059924257

IT (CASTELFRANCO EMILIA) participant 267˙580.00
5    OFFICINE MARIO DORIN SPA

 Organization address address: VIA ARETINA 388
city: FIESOLE FI
postcode: 50061

contact info
Titolo: Dr.
Nome: Lorenzo
Cognome: Fanetti
Email: send email
Telefono: +39 05562321241

IT (FIESOLE FI) participant 252˙090.00
6    KUNGLIGA TEKNISKA HOEGSKOLAN

 Organization address address: Valhallavaegen 79
city: STOCKHOLM
postcode: 10044

contact info
Nome: Sara
Cognome: Karlsson
Email: send email
Telefono: 4687907870
Fax: +46 87906500

SE (STOCKHOLM) participant 27˙520.00
7    UNIVERSITA DEGLI STUDI DI FIRENZE

 Organization address address: Piazza San Marco 4
city: Florence
postcode: 50121

contact info
Titolo: Ms.
Nome: Danielle
Cognome: Fiaschi
Email: send email
Telefono: +39 0554796776

IT (Florence) participant 21˙074.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

power    mode    heating    vapour    cooling    refrigerant    ing    units    heat    throttle    compression    capacity    valve    liquid    pump    performance    kw    pressure    expander   

 Obiettivo del progetto (Objective)

'In vapour-compression cycles (VCC) and more specifically in heat pumps, mechanical work is supplied to the compressor for increasing the pressure of the evaporated refrigerant. Heat is rejected in the condenser (effective heating at heating mode), for the condensation of the refrigerant, which is then expanded in a throttle valve (no power produced), in order to decrease its pressure, resulting to a two-phase mixture. The heat supply to the evaporator (effective cooling at cooling mode) evaporates further the refrigerant. The aim of the EXP-HEAT project is to develop a dedicated component and to integrate it in heat pump units. This component is actually a positive displacement liquid expander with capacity of around 1-2 kW and will replace the throttle valve used in vapour-compression units. Its purpose is to recover the energy of the high-pressure liquid refrigerant, by producing power and assisting in the compression process, reducing the compression work by up to 10-15%. At the same time the heat removed is increased by around 5%, since the expansion of the liquid refrigerant is not isenthalpic. The resulting increase of the Coefficient Of Performance (COP) is expected to reach even 20% at specific operating conditions and for both heating/cooling modes, significantly improving the performance of a heat pump, without major interventions and keeping the additional cost low, in order to ensure the cost-effectiveness of this concept. In order to achieve these targets, the developed expander will be extensively tested under a wide range of operating conditions, in order afterwards to be delivered and integrated in a re-designed heat pump with a capacity of 10-20 kW, and also used for the proper retrofitting of an already installed unit of the same capacity.'

Altri progetti dello stesso programma (FP7-SME)

DEARSUN (2008)

DEvelopment of a direct solAR heating System capable of covering a full-year thermal load UsiNg high temperature thermal storage

Read More  

ECOBUG (2008)

Development of an Innovative Industrial Bioreacting and Fermentation Process producing an Organic Insect Repellent-Fertilizer for Ecological farming

Read More  

PREVENTDFU (2011)

Device for prophylaxis and treatment of diabetic foot ulcers for hospital and home use

Read More