METELCAD

"Development of a Cost Effective, Low-Maintenance, On-Line Instrument to Detect Heavy Metal Concentrations in Wastewaters"

 Coordinatore ATEKNEA SOLUTIONS HUNGARY KFT 

 Organization address address: TETENYI UT 84-86
city: BUDAPEST
postcode: 1119

contact info
Titolo: Ms.
Nome: Melinda
Cognome: Kuthy
Email: send email
Telefono: 3617874024
Fax: 3617874390

 Nazionalità Coordinatore Hungary [HU]
 Sito del progetto http://www.metelcad.eu
 Totale costo 1˙395˙722 €
 EC contributo 1˙015˙081 €
 Programma FP7-SME
Specific Programme "Capacities": Research for the benefit of SMEs
 Code Call FP7-SME-2007-1
 Funding Scheme BSG-SME
 Anno di inizio 2008
 Periodo (anno-mese-giorno) 2008-11-01   -   2011-01-31

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    ATEKNEA SOLUTIONS HUNGARY KFT

 Organization address address: TETENYI UT 84-86
city: BUDAPEST
postcode: 1119

contact info
Titolo: Ms.
Nome: Melinda
Cognome: Kuthy
Email: send email
Telefono: 3617874024
Fax: 3617874390

HU (BUDAPEST) coordinator 0.00
2    AQUA CONCORDE VIZANALITIKAI ES VIZTECHNOLOGIAI KFT

 Organization address address: BOSNYAK TER 11
city: BUDAPEST
postcode: 1145

contact info
Titolo: Dr.
Nome: Tamas
Cognome: Cserfalvi
Email: send email
Telefono: +36 1 4630563
Fax: +3620 3515361

HU (BUDAPEST) participant 0.00
3    ATEKNEA SOLUTIONS CATALONIA, SA

 Organization address address: CALLE VICTOR PRADERA 45
city: CORNELLA DE LLOBREGAT BARCELONA
postcode: 8940

contact info
Titolo: Ms.
Nome: Eva
Cognome: Romagosa
Email: send email
Telefono: +34 932049922
Fax: +34 932049866

ES (CORNELLA DE LLOBREGAT BARCELONA) participant 0.00
4    CENTIV GMBH

 Organization address address: Villinger Weg 10
city: Stuhr
postcode: 28816

contact info
Titolo: Mr.
Nome: Malte
Cognome: Bethke
Email: send email
Telefono: +49 4214608356
Fax: +49 4214609357

DE (Stuhr) participant 0.00
5    INGENIORFIRMA TISON TITLESTAD AS

 Organization address address: LEIRVIKASEN 39 B
city: GODVIK
postcode: 5179

contact info
Titolo: Mr.
Nome: Ove Martin
Cognome: Nedregotten
Email: send email
Telefono: +47 55298182
Fax: +47 55295632

NO (GODVIK) participant 0.00
6    MALEX ZAKLAD UTYLIZACJI ODPADOW MONIKA MALICKA

 Organization address address: UL. WERNERA JERZEGO PROF 23
city: LODZ
postcode: 91 169

contact info
Titolo: Ms.
Nome: Monika
Cognome: Malicka
Email: send email
Telefono: +48 42 714 0149
Fax: +48 42 716 4410

PL (LODZ) participant 0.00
7    PERMASTORE LIMITED

 Organization address address: AIRFIELD INDUSTRIAL PARK
city: "EYE, SUFFOLK"
postcode: IP23 7HS

contact info
Titolo: Mr.
Nome: Saqlain
Cognome: Ali
Email: send email
Telefono: +44 1379 870723
Fax: +44 1379 870530

UK ("EYE, SUFFOLK") participant 0.00
8    PURITY CONTROL SPOL S.R.O.

 Organization address address: PREMYSLOVCU 30
city: OSTRAVA
postcode: 70900

contact info
Titolo: Mr.
Nome: Petr
Cognome: Silhan
Email: send email
Telefono: +420 596632129
Fax: +420 596632139

CZ (OSTRAVA) participant 0.00
9    WATER SERVICES CORPORATION - WSC

 Organization address address: Qormi Road
city: LUQA
postcode: LQA 9043

contact info
Titolo: Mr.
Nome: Paul
Cognome: Micallef
Email: send email
Telefono: +356 2244 3231
Fax: +356 2244 3900

MT (LUQA) participant 0.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

ferrous    environmental    industrial    metals    contaminated    wastewater    health    environment    water    before    heavy    industry    metelcad    sludge    metal   

 Obiettivo del progetto (Objective)

'All contaminated water, whether originating in industry, agriculture or households, causes damage to the environment and to human health. Industrial wastewater, contaminated by heavy metals, migrates to surface and underground water sources. Heavy metals are elements that have a high density and are toxic or poisonous even at low concentrations. In addition to wastewater, sewer sludge, the residual semi-solid material remaining from urban and industrial wastewater treatment processes, also contains high levels of heavy metals. Consortium members of the current METELCAD project recognize that with the advent of increasing environmental EC Directives, there is a critical need in Europe to develop a low cost, and efficient detection technology for metal contaminated wastewater to safeguard public health and reduce pollution and clean up costs. METELCAD will allow consortium SMEs to detect heavy metal presence in industrial wastewater before it is released into the environment or before it reaches the sludge stage. The commercial objective of the proposal is to develop an on-line, low maintenance, on-site, continuous monitoring technology utilizing electrolyte cathode glow discharge technique to monitor heavy metal contaminated wastewaters that are loaded with high fat emulsion. This cost-effective technology will facilitate compliance with EU environmental legislation in a business-friendly manner, facilitating industrial wastewater management. The proposed technology is also relevant to other industrial sectors including ferrous and non-ferrous metals industry.'

Altri progetti dello stesso programma (FP7-SME)

TOXDTECT (2013)

Innovative Packaging for the Detection of Fresh Meat Quality and Prediction of Shelf-Life

Read More  

POWDERBOND (2013)

Developing powder coatings for contact curing of structural adhesives for vehicle bonding applications

Read More  

POC4PETS (2012)

Point of Care Diagnostics for rapid and cheap pathogen detection of companion animals

Read More